Part 1 Pumping Unit The Chinese manufacturers started to produce pumping units in 1950’ s and have been API and ISO 9000 certified ever since 1980’ s. Annual production capability of pumping unit: 20, 000 sets Standard: API spec11E and China oil & gas industry standard Models of pumping units: All API models, up to 1280, 000 in.-lbs Torque range of reducer: 25, 50, 80, 114, 160, 228, 320, 456, 640, 912, 1280 (¡Á1000) in.-lbs Suspension Load: 5, 300-36, 500 lbs Stroke Length: 30-192 in 
CPTDC has provided the China-made pumping units to the United States, Russia, Indonesia, Sudan and Venezuela. ● Features ● The strength of critical parts is calculated and checked by using finite element analysis. ● Special clamping fixtures and instruments are used in the manufacturing process of the main components to ensure proper fit and performance. ● Every unit has type approval test. ● Modular design allows parts to be easily interchanged and replaced. 1. Conventional Walking Beam Pumping Unit Main specifications of conventional beam pumping unit according to API standards | Model (API) | Rated torque (lbs. in) | Load (lbs) | Stroke (in) | Main specifications of conventional beam pumping unit according to API standards | Model (API) | Rated torque (lbs. in) | Load (lbs) | Stroke (in) | C-1280-305-240 | 1, 280, 000 | 30, 500 | 240, 209, 179, 151 | C-912-365-192 C-912-365-168 C-912-365-144 C-912-427-144 C-912-305-192 C-912-305-168 | 912, 000 | 36, 500 36, 500 36, 500 42, 700 30, 500 30, 500 | 192, 165, 138 168, 144, 121 144, 123, 102 144, 123, 102 192, 168, 145 168, 144, 121 | C-640-365-168 C-640-305-192 C-640-305-168 C-640-365-144 C-640-305-144 C-640-256-144 C-640-256-192 C-640-305-120 | 640, 000
| 36, 500 30, 500 30, 500 36, 500 30, 500 25, 600 25, 600 30, 500 | 168, 144, 121 192, 168, 144 168, 144, 121 144, 123, 102 144, 123, 102 144, 123, 102 192, 165, 142 120, 102, 84 | C-456-305-168 C-456-305-144 C-456-256-144 C-456-365-120 C-456-305-120 C-456-256-120 C-456-213-168 C-456-213-120 C-456-256-100 | 456, 000
| 30, 500 30, 500 25, 600 36, 500 30, 500 25, 600 21, 300 21, 300 25, 600 | 168, 144, 121 144, 123, 102 144, 123, 102 120, 102, 84 120, 102, 84 120, 102, 84 168, 145, 124 120, 102, 84 100, 85, 70 | C-320-256-144 C-320-256-120 C-320-213-120 C-320-305-100 C-320-256-100 C-320-256-86 C-320-213-86 C-320-246-74 | 320, 000
| 25, 600 25, 600 21, 300 30, 500 25, 600 24, 600 21, 300 24, 600 | 144, 123, 102 120, 102, 84 120, 102, 84 100, 85, 70 100, 85, 70 86, 74, 62 86, 74, 62 74, 64, 53 |
C-228-185-144 C-228-213-120 C-228-213-100 C-228-173-120 C-228-173-100 C-228-246-86 C-228-213-86 C-228-200-74 C-228-173-74 | 228, 000
| 18, 500 21, 300 21, 300 17, 300 17, 300 24, 600 21, 300 20, 000 17, 300 | 144, 127, 109 120, 102, 84 100, 86, 72 120, 102, 84 100, 86, 72 86, 74, 62 86, 74, 62 74, 64, 53 74, 64, 53 | C-160-173-100 C-160-173-86 C-160-200-74 C-160-173-74 C-160-143-74 | 160, 000
| 17, 300 17, 300 20, 000 17, 300 14, 300 | 100, 86, 72 86, 74, 62 74, 64, 53 74, 63, 52 74, 63, 52 | C-114-119-100 C-114-119-86 C-114-143-74 C-114-173-64 C-114-143-64 C-114-173-54 | 114, 000
| 11, 900 11, 900 14, 300 17, 300 14, 300 17, 300 | 100, 86, 72 86, 73, 60 74, 63, 52 64, 55, 45 64, 53, 42 54, 44, 34 | C-80-89-64 C-80-67-64 | 80, 000
| 8, 900 6, 700 | 74, 64, 54 64, 48, 36 | C-57-109-48 C-57-95-48 C-57-89-42 C-57-76-54 C-57-76-42 | 57, 000
| 10, 900 9, 500 8, 900 7.600 7, 600 | 48, 37, 23 48, 37, 23 42, 33, 23 54, 45, 36 42, 33, 23 | C-40-76-48 C-40-89-42 C-57-76-42 C-40-89-36 | 40, 000
| 7, 600 8, 900 7, 600 8, 900 | 48, 37, 23 42, 33, 23 42, 33, 23 36, 28, 20 | C-25-67-36 C-25-56-36 C-25-67-30 C-25-53-30 | 25, 000
| 6, 700 5, 600 6, 700 5, 300 | 36, 28, 20 36, 28, 20 30, 20 30, 20 |


Conventional Pumping Units manufactured according to China National Standard ● Models and Specifications Model (CYJ) | Rated torque of reducer kN.m (lbs.in) | Max rod load kN. (lbs) | Max Stroke m (in) | CYJ3-1.8-13HB CYJ5-1.8-13HB CYJ5-2.1-13HB CYJ6-2.5-26HB CYJ8-3-48HB CYJ10-3-37HB CYJ10-3-53HB CYJ12-5-73HB CYJ16-6-105HB CYJ11-3-48HB CYJ12-3.2-70HB CYJ12-3.6-73HB CYJ12-4.2-73HB CYJ12-4.8-73HB CYJ12-5-73HB CYJ14-5.5-105HB CYJ16-6-105HB CYJ20-4.2-53HB | 13 (114, 000) 13 (114, 000) 13 (114, 000) 26 (228, 000) 48 (420, 000) 37 (320, 000) 53 (456, 000) 73 (640, 000) 105 (912, 000) 48 (420, 000) 70 (610, 000) 73 (640, 000) 73 (640, 000) 73 (640, 000) 73 (640, 000) 105 (912, 000) 105 (912, 000) 53 (456, 000) | 30 (6, 700) 50 (11, 200) 50 (11, 200) 60 (13, 200) 80 (17, 300) 100 (21, 300) 100 (21, 300) 120 (25, 600) 160 (36, 500) 110 (24, 600) 120 (25, 600) 120 (25, 600) 120 (25, 600) 120 (25, 600) 120 (25, 600) 140 (31, 500) 160 (36, 500) 200 (42, 600) | 1.8 (71) 1.8 (71) 2.1 (83) 2.5 (98) 3 (118) 3 (118) 3 (118) 5 (196) 6 (236) 3 (118) 3.2 (130) 3.6 (142) 4.2 (165) 4.8 (189) 5 (197) 5.5 (216) 6 (236) 4.2 (165) |

2. Special Pumping Unit Double Horse-head Walking Beam Pumping Unit The rear part of this unit is a changing radius arc connected to the equalizer beam by a flexible joint. This configuration eliminates the dead angle restriction, enlarges the walking beam pivot range, and increases the stroke by 20% to 70%. In working condition, the regular changing length of rear part makes the counterbalance moment increase and decrease along with load increasing and decreasing. This structure makes the whole unit with low fluctuation, good balanced state and reduces energy consumption by 30% to 60%. |  |
● Models and Specifications of Double Horse-head Pumping Units Model (API) | Rated torque of Reducer (lbs. in) | Max rod load lbs | Stroke in | CA640-365-240 CA640-305-200 CA640-256-200 CA456-305-200 CA456-256-200 CA320-256-200 CA320-213-200 CA228-173-120 | 640, 000 640, 000 640, 000 456, 000 456, 000 320, 000 320, 000 228, 000 | 36, 500 30, 500 25, 600 30, 500 25, 600 25, 600 21, 300 17, 300 | 240, 192, 144 200, 160, 120 200, 160, 120 200, 160, 120 200, 160, 120 200, 160, 120 200, 160, 120 120, 104, 84 |
Model (CYJ) | Rated torque of reducer (kN.m) | Max rod load kN | Stroke m | YCYJ16-6-89HB YCYJ16-6-73HB YCYJ14-5-73HB YCYJ12-5-73HB YCYJ14-5-53HB YCYJ12-5-53HB YCYJ12-5-48HB YCYJ10-5-48HB YCYJ10-5-37HB YCYJ8-3-26HB YCYJ6-3-18HB YCYJ4-2.5-13HB YCYJ3-2.5-9HB | 89 73 73 73 53 53 48 48 37 26 18 13 9 | 160 160 140 120 140 120 120 100 100 80 60 40 30 | 6, 4.8, 3.6 6, 4.8, 3.6 5, 4, 3 5, 4, 3 5, 4, 3 5, 4, 3 5, 4, 3 5, 4, 3 5, 4, 3 3, 2.6, 2.1 3, 2.6, 2.1 2.5, 2.1, 1.8 2.5, 2.1, 1.8 | CYJBL10-4.2-37HB CYJBL8-3-26HB CYJBL6-2.5-18HB CYJBL10-3-26HB | 37 26 48 26 | 100 80 60 100 | 3, 3.6, 4.2 1.8, 2.4, 3 1.8, 2.5 3, 2.4, 1.8 |
Phased Crank Counterbalance Pumping Unit The main difference between this pumping unit and the conventional pumping unit is that a phase angle between crank pin center line and counterbalance weight centerline causes the movement of crank shaft out of phase with the torque produced by load. This structure makes the net torque curve smooth, reduces the peak torque value, prolongs service life and reduces energy consumption. ● Models and Specifications of Phased Crank Counterbalance Pumping Units |  |
Model (CYJY) | CYJY4-1.5-9HB | CYJY5-2.5-26HB | CYJY10-3-37HB | CYJY12-3.6-53HB | CYJY10-4.2-53HB | Model (API) | 80-89-59 | 228-110-100 | 320-213-120 | 456-256-144 | 456-213-168 | Rated rod load kN (lbs) | 40 (8, 900) | 50 (11, 000) | 100 (21, 300) | 120 (25, 600) | 100 (21, 300) | Rated torque of reducer kN.m (lbs. in) | 9 (80, 000) | 26 (228, 000) | 37 (320, 000) | 53 (456, 000) | Drive ratio of reducer | 31.73 | 29.5 | 29.43 | 30.8 | SPM-Max s/min | 15 | 16 | 14 | 12 | 10 | Stroke mm (in) | 1, 500/59 | 2, 540/100 | 3, 000/120 | 3, 600/144 | 4, 200/168 | 1, 200/47 | 2, 110/79 | 2, 400/94 | 3, 000/120 | 3, 600/144 | 900/35 | 1, 535/60 | 1, 800/71 | 2, 390/94 | 3, 000/120 |
Model (CYJY) | CYJY16-4.2-73HB | CYJY12-4.8-73HB | CYJY14-5.5-89HB | CYJY16-6-105HB | Model (API) | 640-365-168 | 640-256-192 | 773-305-216 | 912-365-240 | Rated rod load kN (lbs) | 160 (36, 500) | 120 (25, 600) | 140 (30, 500) | 160 (36, 500) | Rated torque of reducer kN .m (lb. in) | 73 (640, 000) | 89 (773, 000) | 105 (912, 000) | Drive ratio of reducer | 31.73 | 39.25 | 35.43 | SPM-Max s/min | 9 | 8 | 8 | Stroke mm (in) | 4, 200/168 | 4, 878/192 | 5, 500/216 | 6, 096/240 | 3, 600/144 | 4, 013/158 | 4, 800/189 | 5, 200/204 | 3, 000/120 | 3, 226/127 | 4, 200/168 | 4, 500/177 |
Bent Beam Pumping Unit The rear of the walking beam is a bent shape that provides more posts for adjusting beam balance as required. The balance movement of the walking beam varies as the horse-head moves up and down. The bent end of the walking beam modifies the crank balance curve, and the compound torque curve conforms to the load torque curve, smoothing out and reducing peaks in the net torque curve. This reduces the rated torque of the gear reducer and rated power of electric motor, putting structural parts under less stress and reducing power consumption by over 30%. ● Models and Specifications of Bent Beam Pumping Units |  |
Model (API) | Rated torque of reducer (lbs.in) | Max rod load lbs | Stroke (in) | Model (CYJ) | Rated torque of reducer (kN.m) | Max rod load kN | Stroke (m) | CB912-365-216 CB912-365-192 CB912-365-168 CB912-305-192 CB912-305-168 CB640-365-192 CB640-365-168 CB640-305-192 CB640-305-168 CB456-305-192 CB456-305-168 CB456-305-144 CB320-256-192 CB320-256-168 CB320-256-144 CB320-256-120 CB320-213-192 CB320-213-168 CB228-213-144 CB228-213-120 CB160-173-120 CBl14-133-120 | 912, 000 912, 000 912, 000 912, 000 912, 000 640, 000 640, 000 640, 000 640, 000 456, 000 456, 000 456, 000 320, 000 320, 000 320, 000 320, 000 320, 000 320, 000 228, 000 228, 000 160, 000 114, 000 | 36, 500 36, 500 36, 500 30, 500 30, 500 36, 500 36, 500 30, 500 30, 500 30, 500 30, 500 30, 500 25, 600 25, 600 25, 600 25, 600 21, 300 21, 300 21, 300 21, 300 17, 300 13, 300 | 216, 192, 168 192, 168, 144 168, 144, 120 192, 168, 144 168, 144, 120 192, 168, 144 168, 144, 120 192, 168, 144 168, 144, 120 192, 168, 144 168, 144, 120 144, 120, 86 192168, 144 168, 144, 120 144, 120, 86 120, 100, 74 192, 168, 144 168, 144, 120 144, 120, 86 120, 100, 86 120, 100, 86 120, 100, 86 | CYJU16-5.5-105F CYJU 16-4.8-105F CYJU 16-4.2-105F CYJU16-4.8-89F CYJU 16-4.2-89F CYJU14-4.8-105F CYJU 14-4.2-105F CYJU14-4.8-89F CYJU14-4.2-89F CYJU14-4.8-73F CYJU14-4.2-73F CYJUI4-3.6-73F CYJU 12-4.8-53F CYJU12-4.2-53F CYJU12-3.6-53F CYJU12-3-53F CYJU10-4.8-48F CYJU10-4.2-48F CYJU10-3.6-37F CYJU10-3-37F CYJU8-3-26F CYJU6-3-18F | 105 105 105 89 89 105 105 89 89 73 73 73 53 53 53 53 48 48 37 37 26 18 | 160 160 160 160 160 140 140 140 140 140 140 140 120 120 120 120 100 100 100 100 80 60 | 5.5, 4.7, 4 4.8, 4.2, 3.6 4.2, 3.6, 3 4.8, 4.2, 3.6 4.2, 3.6, 3 4.8, 4.2, 3.6 4.2, 3.6, 3 4.8, 4.2, 3.6 4.2, 3.6, 3 4.8, 4.2, 3.6 4.2, 3.6, 3 3.6, 3.2, 2.1 4.8, 4.2, 3.6 4.2, 3.6, 3 3.6, 3, 2.1 3, 2.5, 1.8 4.8, 4.2, 3.6 4.2, 3.6, 3 3.6, 3, 2.1 3, 2.5, 1.8 3, 2.5, 2.1 3, 2.5, 2.1 |
Compound Balance Pumping Unit Compound balance pumping units are similar to conventional pumping units, but there is a balancing counterweight on the rear end of the beam to balance the load jointly with the crank balance. The working principle is also similar to that of conventional units, but the beam balance spreads out the peak load to improve the balancing effect and decrease stress on the bar members. |  |
● Models and Specifications of Compound Balance Pumping Units Model
| Rated torque of reducer (kN.m)
| Max rod load (kN)
| Stroke (m)
| CYJY4-1.5-9HF | 9 | 40 | 0.9, 1.2, 1.5 | CYJY5-1.8-13HF | 13 | 50 | 0.9, 1.3, 1.8 | CYJY6-2.5-26HF | 26 | 60 | 1.2, 1.8, 2.5 | CYJY6-2.5-18HF | 18 | 60 | 1.2, 1.8, 2.5 | CYJY6-2.5-26HF | 26 | 80 | 1.8, 2.4, 2.5 | CYJY10-3-37HF | 37 | 100 | 1.8, 2.4, 3 |
Front-mounted Crank Balance Pumping Unit The construction of front mounted pumping units is quite different from that of conventional pumping units. The pitman, crank mechanism and horse-head are all mounted on the front side of the samson post bearing, and the balance counterweight and pitman are mounted on each end of the crank. These pumping units have the advantages of longer strokes and lower power use. |  |
● Models and Specifications of Front-mounted Crank Balance Pumping Units Model (CYJ) | CYJQ12-3.6- 37HB | CYJQ12-3.6-53HB | CYJQ14-4.2-53HB | CYJQ14-3.6-73HB | CYJQ14-4.2-73HB | Model (API) | 320-256-144 | 456-256-144 | 456-305-168 | 640-305-144 | 640-305-168 | Rated rod load kN (lbs) | 120 (25, 600) | 120 (25, 600) | 140 (30, 500) | 140 (30, 500) | 140 (30, 500) |
Rated torque of reducer kN.m (lbs.in) | 37 (320, 000) | 53 (456, 000) | 73 (640, 000) | Drive ratio of reducer | 30.68 | 30.8 | 31.73 | SPM-Max s/min | 12 | 12 | 10 | 12 | 10 | Stroke mm (in) | 3, 658/144 | 3, 656/144 | 4, 267/168 | 3, 658/144 | 4, 267/168 | 3, 251/128 | 3, 251/128 | 3, 785/149 | 3, 251/128 | 3, 785/149 | 2, 845/112 | 2, 845/112 | 3, 302/130 | 2, 854/112 | 3, 302/130 |
Model (CYJ) | CYJQ14-4.8 -73HB | CYJQ14-4.2 -105HB | CYJQ14-4.8 -105HB | CYJQ14-5.5 -105HB | CYJQ16-6 -105HB | Model (API) | 640-305-192 | 912-305-168 | 912-305-192 | 912-305-216 | 912-365-240 | Rated rod load kN (lbs) | 140 (30, 500) | 140 (30, 500) | 140 (30, 500) | 140 (30, 500) | 160 (36, 500) | Rated torque of reducer kN.m (lbs in) | 73 (640, 000) | 105 (912, 000) | Drive ratio of reducer | 31.73 | 35.43 79.43 | SPM-Max s/min | 8 | 10 | 8 | Stroke mm (in) | 4, 877/192 | 4, 267/168 | 4, 877/192 | 5, 486/216 | 6, 000/240 | 4, 267/168 | 3, 785/149 | 4, 267/168 | 4, 877/192 | 5, 000/196 | 3, 658/144 | 3, 302/130 | 3, 658/144 | 4, 242/167 | 4, 000/157 |
Numerically Controlled Pumping Unit The features of numerical control pumping unit are as follows: ● The speed regulation of up-stroke and down-stroke of numerically controlled pumping units is stepless. The Max stroke length is 12 m (which can be lengthened according to the customer’s requirements). The running conditions of the unit are extremely smooth with surge absorption. Its load capacity reaches 200 kN. ● Compact construction: The overall size is 3.2 m×1.2 m×1.2 m. It is particularly suitable for production on offshore platform. ● The modular design of main components ensures the interchangeability of components and easy maintenance and service. ● Adopting AC frequency conversion and computer-aided technology for speed control, easy for operation and energy saving. |  |
● Models and Specifications of Numerically Controlled Pumping Units Model | Rated torque kN.m (lb¡¤in) | Max load kN (lbs) | Motor power kW (HP) | Max stroke m (in) | SKC6-4-7.2 SKC6-5-7.2 SKC6-6 -12 SKC6-8-12 SKC6-10-12 SKC8-6-12 SKC8-8-18 SKC8-10-18 SKC10-6-18 SKC10-8-18 SKC10-10-18 SKC12-6-18 SKC12-8-18 SKC12-10-18 SKC12-12-30 SKC14-6-18 SKC14-8-18 SKC14-10-30 SKC14-12-30 SKC16-6-18 SKC16-8-18 SKC16-10-30 SKC16-12-30 SKC20-6-30 SKC20-8-30 SKC20-l 0-60 SKC20-12-60 | 7.2 (63, 763) 7.2 (63, 763) 12 (106, 272) 12 (106, 272) 12 (106, 272) 12 (106, 272) 18 (159, 408) 18 (159, 408) 18 (159, 408) 18 (159, 408) 18 (159, 408) 18 (159, 408) 18 (159, 408) 18 (159, 408) 20 (177, 120) 18 (159, 408) 18 (159, 408) 30 (265, 680) 30 (265, 680) 18 (159, 408) 18 (159, 408) 30 (265, 680) 30 (265, 680) 30 (265, 680) 30 (265, 680) 60 (531, 360) 60 (531, 360) | 60 (13, 500) 60(13, 500) 60 (13, 500) 60 (13, 500) 60 (13, 500) 80 (18, 000) 80 (18, 000) 80 (18, 000) 100 (22, 500) 100 (22, 500) 100 (22, 500) 120 (27, 000) 120 (27, 000) 120 (27, 000) 120 (27, 000) 140 (31, 500) 140 (31, 500) 140 (31, 500) 140 (31, 500) 160 (36, 000) 160 (36, 000) 160 (36, 000) 160 (36, 000) 200 (45, 000) 200 (45, 000) 200 (45, 000) 200 (45, 000) | 11-22 (14.96-29.92) 11-22 (14.96-29.92) 15-30 (20.4-40.8) 15-30 (20.4-40.8) 15 -30 (20.4-40.8) 15-30 (20.4-40.8) 15-30 (20.4-40.8) 15-30 (20.4-40.8) 15-30 (20.4-40.8) 15-30 (20.4-40.8) 15-30 (20.4-40.8) 15-30 (20.4-40.8) 15-30 (20.4-40.8) 15-30 (20.4-40.8) 22-55 (29.92-74.8) 15 -30 (20.4-40.8) 15-30 (20.4-40.8) 22-55 (29.92-74.8) 22-55 (29.92-74.8) 15-30 (20.4-40.8) 15-30 (20.4-40.8) 22-55 (29.92-74.8) 22-55 (29.92-74.8) 22-55 (29.92-74.8) 22-55 (29.92-74.8) 37-75 (50.32-102) 37-75 (50.32-102) | 4 (157.5) 5 (196.8) 6 (236.2) 8 (315) 10 (393.7) 6 (236.2) 8 (315) 10 (393.7) 6 (236.2) 8 (315) 10 (393.7) 6 (236.2) 8 (315) 10 (393.7) 12 (472.4) 6 (236.2) 8 (315) 10 (393.7) 12 (472.4) 6 (236.2) 8 (315) 10 (393.7) 12 (472.4) 6 (236.2) 8 (315) 10 (393.7) 12 (472.4) |
Linear Motor Actuated Pumping Unit The linear motor actuated pumping unit, different from traveling beam pumping unit, which converts electric power into rotation power at first and then into linear reciprocating movement in mechanical way, can directly convert electric power into linear reciprocating movement by using linear motor to simplify the mechanical drive process. ● Features High transmission efficiency Small dynamic and inertial load Small energy consumption Light weight Long service life Convenient for intellectualized and automatic control Wide application scope |  |
● Models and Specifications of Linear motor Actuated Pumping Unit Model | Structure capacity mt (lb) | Max stroke M (ft) | Motor thrust mt (lb) | Power (kW) | Zxcy5-3-15-Ⅰ | 5 (11, 000) | 3 (10) | 1.5 (3, 300) | 9 | Zxcy8-3-20-Ⅰ | 8 (17, 000) | 3 (10) | 2.0 (4, 400) | 13 | Zxcy10-4.2-20-Ⅰ | 10 (22, 000) | 4.2 (14) | 2.0 (4, 400) | 18 | Zxcy12-6-30-Ⅰ | 12 (26, 000) | 6 (20) | 3.0 (6, 600) | 24 | Zxcy14-6-30-Ⅰ | 14 (30, 000) | 6 (20) | 3.0 (6, 600) | 30 | Zxcy14-6-45-Ⅰ | 14 (30, 000) | 6 (20) | 4.5 (9, 900) | 30 | Zxcy16-6-45-Ⅰ, Ⅱ | 16 (35, 200) | 6 (20) | 4.5 (9, 900) | 40 | Zxcy16-6-60-Ⅰ, Ⅱ | 16 (35, 200) | 6 (20) | 6.0 (13, 200) | 40 | Zxcy16-8-60-Ⅰ, Ⅱ | 16 (35, 200) | 8 (26) | 6.0 (13, 200) | 40 | Zxcy18-6-45-Ⅰ, Ⅱ | 18 (39, 600) | 6 (20) | 4.5 (9, 900) | 54 | Zxcy18-6-60-Ⅰ, Ⅱ | 18 (39, 600) | 6 (20) | 6.0 (13, 000) | 54 | Zxcy18-8-60-Ⅰ, Ⅱ | 18 (39, 600) | 8 (26) | 6.0 (13, 000) | 54 | Remarks:Ⅰ: Integrated, Ⅱ: Modular |
Moving Belt Pumping Unit The moving belt pumping unit is especially suitable for deep or high production well. The flow rate is up to 250 m3/d, also is suitable for heavy oil production. Compared with other artificial lift systems, the moving belt pumping unit has the following advantages: Long, slow pump stroke The stroke length can be as long as 7.3 m, significantly reducing downhole pump wear. Saving power consumption by 10-40% Smooth, noiseless and vibration-less operation Compact profile, easy to ship and assemble 
● Models and Specifications of Moving Belt Pumping Units Model | 900 | 800 | 700 | 600 | Stroke length m (ft) | 7.3 (23.95) | 7.0 (22.96) | 6.0 (19.68) | 5.0 (16.4) | Peak polished rod load kg (lbs) | 16, 310 (35, 957) | 14, 000 (30, 864) | 12, 000 (26, 455) | 10, 000 (22, 045) | SPM-Max s/min | 4 | 5.3 | SPM-Min s/min | No Absolute Minimum | Shipping weight kg (lbs) | 19, 500 (42, 900) | 17, 500 (38, 580) | 15, 500 (34, 171) | 13, 500 (29, 762) | Unit width m (ft) | 2.4 (7.87) | 2.2 (7.22) | Unit height m (ft) | 12.4 (40.68) | 11.1 (36.42) | 10.1 (33.14) | 9.2 (30.18) |

Gear Reducer ● Two types of gear tooth profiles ● Involutes profile tooth-conforming to API Spec11E ● Double circular arc tooth profile-invented in China, now widely used ● Features Smooth running, small size, low noise and high load capacity
3. Electrical Motor The electrical motors include synchronous motors and asynchronous motors, which can be classified according to rotation speed and control mode (Low rotation speed or high rotation speed, VFD control or FFD control electrical motors are available). YCH Series High Slip Induction Motor Enclosure: Totally Enclosed Fan Cooled (TEFC) Frame Material: Cast Aluminum. Insulation Class: E YCH Series High Slip Induction Motors Temperature rise: 80 ℃, Class B Voltage: 460 V/60 Hz/3 Phase, NEMA Design: D (7.5% Slip), Service Factor: 1.15 Starting condition: Full Voltage, Space Heater: 12 V A.C. Environmental Exposure: Fungus and High Humidity Thermal protection with three (3) thermostats (1 per phase) |  |
● Models and Specifications of NEMA D Series High Slip Motors ◆Synchronization speed: 1200 RPM 460 V 60 Hz Model | Frame | Nameplate horsepower | Full load amp. | Full load RPM | Slip | Efficiency | Power factor | L.R. Torque (N.m) | Locked rotor Amp. | YCH180-6 | 286T | 20 (15 kW) | 26.3 | 1, 111 | 7.41 | 83.00 | 0.861 | 326 | 130 | YCH200-6 | 326T | 30 (22 kW) | 37.9 | 1, 104 | 7.98 | 83.39 | 0.873 | 438 | 175 | YCH200-1-6 | 326T | 35 (25 kW) | 43.3 | 1, 121 | 6.57 | 85.47 | 0.843 | 690 | 252 | YCH225-6
| 365T
| 50 (37 kW)
| 60.9
| 1, 105
| 7.88
| 84.32
| 0.904
| 863
| 318
| YCH250-6
| 405T
| 60 (45 kW)
| 73.0
| 1, 119
| 6.68
| 85.75
| 0.903
| 1, 102
| 425
| YCH280-6
| 445T
| 85 (63 kW)
| 101.4
| 1, 119
| 6.76
| 86.29
| 0.904
| 1, 898
| 647
| YCH280L-8
| 445T
| 100 (75 kW)
| 120.7
| 1, 114
| 7.19
| 86.49
| 0.902
| 3, 041
| 858
|
◆Synchronization speed: 900 RPM 460 V 60 Hz YCH180-8
| 286T
| 15 (11 kW)
| 21.9
| 824
| 8.36
| 80.70
| 0.781
| 296
| 88.5
| YCH200-8
| 326T
| 20 (15 kW)
| 29.6
| 833
| 7.42
| 83.01
| 0.767
| 437
| 130
| YCH200-1-8
| 326T
| 25 (18.5 kW)
| 36.8
| 832
| 7.55
| 83.26
| 0.759
| 618
| 170
| YCH225-8
| 365T
| 35 (25 kW)
| 46.0
| 839
| 6.74
| 85.04
| 0.802
| 1, 010
| 263
| YCH250-8
| 405T
| 45 (33 kW)
| 59.6
| 840
| 6.71
| 85.33
| 0.829
| 1, 193
| 328
| YCH280-8
| 445T
| 60 (45 kW)
| 79.1
| 834
| 7.35
| 85.18
| 0.839
| 1, 865
| 454
| YCH280L-8
| 445T
| 75 (55 kW)
| 93.9
| 840
| 6.69
| 86.40
| 0.851
| 2, 051
| 546
|
◆Synchronization speed: 1000 RPM 380 V 50 Hz YCH180-8
| 286T
| 10 (7.5 kW)
| 19.1
| 686
| 8.50
| 79.39
| 0.750
| 285
| 80
| YCH200-8
| 326T
| 15 (11 kW)
| 27.4
| 688
| 8.22
| 81.15
| 0.750
| 428
| 118
| YCH200-1-8
| 326T
| 20 (15 kW)
| 36.6
| 689
| 8.10
| 81.62
| 0.763
| 545
| 157
| YCH225-8
| 365T
| 25 (18.5 kW)
| 42.8
| 694
| 7.50
| 83.41
| 0.787
| 965
| 235
| YCH250-8
| 405T
| 35 (25 kW)
| 55.4
| 693
| 7.66
| 83.57
| 0.821
| 1, 151
| 296
| YCH280-8
| 445T
| 45 (33 kW)
| 72.7
| 689
| 8.08
| 83.73
| 0.824
| 1, 761
| 405
| YCH280L-8
| 445T
| 60 (45 kW)
| 95.1
| 688
| 8.33
| 84.05
| 0.855
| 1, 986
| 494
|
◆Synchronization speed: 750 RPM 380 V 50 Hz YCH180-8
| 286T
| 15 (11 kW)
| 21.9
| 824
| 8.36
| 80.70
| 0.781
| 296
| 88.5
| YCH200-8
| 326T
| 20 (15 kW)
| 29.6
| 833
| 7.42
| 83.01
| 0.767
| 437
| 130
| YCH200-1-8
| 326T
| 25 (18.5 kW)
| 36.8
| 832
| 7.55
| 83.26
| 0.759
| 618
| 170
| YCH225-8
| 365T
| 35 (25 kW)
| 46.0
| 839
| 6.74
| 85.04
| 0.802
| 1, 010
| 263
| YCH250-8
| 405T
| 45 (33 kW)
| 59.6
| 840
| 6.71
| 85.33
| 0.829
| 1, 193
| 328
| YCH280-8
| 445T
| 60 (45 kW)
| 79.1
| 834
| 7.35
| 85.18
| 0.839
| 1, 865
| 454
| YCH280L-8
| 445T
| 75 (55 kW)
| 93.9
| 840
| 6.69
| 86.40
| 0.851
| 2, 051
| 546
|
Energy-saving Package Transformer and Control Box ● Specifications of Energy-Saving Package Transformers Voltage kV
| Weight
| Overall dimensions (L¡ÁW¡ÁH)
| HT
| LT
| kg
| lbs
| mm
| in
| 30
|
| 415
| 915
| 990×650×1, 140
| 38.9×25.5×44.8
| 50
|
| 522
| 1, 150
| 1, 070×690×1, 190
| 42.1×27.1×46.8
| 63
|
| 590
| 1, 300
| 1, 090×711×1, 210
| 42.9×27.9×47.6
| 80
|
| 643
| 1, 417
| 1, 210×780×1, 374
| 47.6×30.7×54.0
| 100
| 0.38
| 755
| 1, 644
| 1, 230×870×1, 160
| 48.4×34.2×45.6
| 125
|
| 885
| 1, 951
| 1, 330×900×1, 240
| 52.3×35.4×48.8
| 160
|
| 1, 025
| 2, 259
| 1, 480×910×1, 280
| 58.2×35.8×50.3
| 200
|
| 1, 166
| 2, 570.5
| 1, 500×920×1, 300
| 59.0×36.2×51.1
| 250
|
| 1, 245
| 2, 744.7
| 1, 410×1, 000×1, 540
| 55.5×39.3×60.6
| 315
|
| 1, 430
| 3, 152.5
| 1, 460×1, 010×1, 680
| 57.4×39.7×66.1
|
● Specifications of Control Box Model
| Voltage kV
| Current A
| Overall dimensions (L¡ÁW¡ÁH)
| QYK-A
| 600-2, 500
|
|
| QYK-B
| 600-2, 500
| ≤100
| 960×702×1, 730 (37.7×27.6×38.1)
| WZK-100
| 900-2, 500
|
| 760×563×1, 650 (29.9×22.1×64.9)
| QYK-500
| 500-1, 200
| ≤150
| 600×550×1, 600 (23.6×21.7×63.0)
| QYK-1200
| 1200-3, 000
| ≤100
| 600×550×1, 600 (23.6×21.7×63.0)
|

Rare Earth Permanent Magnet Three Phase Synchronous Motor Permanent magnet synchronous motors with large starting torque can reduce energy consumption than asynchronous motors by 25%. A 37 kW synchronous motor can replace a 55 kW asynchronous motor. These motors can realize asynchronous starting and synchronous running. They have the same size of Y-series asynchronous motors. Stator construction is similar to that of asynchronous motors, and F grade insulation is used. The motor includes two parts: squirrel-cage and permanent magnet. ● Models and Specifications of Rare Earth Permanent Magnet 3-Phase Synchronous Motors Model
| Rated power | Rated speed
| Max torque multiple | Rated cable voltage | Rated efficiency | Starting torque multiple | Rated frequency | Rated power factor | Starting current multiple | YJ43
| 37 kW
| 1, 000 rpm
| 1.7
| 380 V
| 93.8%
| 3.0
| 50 Hz
| 0.93
| 11
| YJ44
| 37 kW
| 750 rpm
| 1.7
| 380 V
| 94.2%
| 3.0
| 50 Hz
| 0.93
| 10.5
|
|
|
|
|
|