Oil Production Equipment

Pumping Unit
Subsurface Sucker Rod Pump
Sucker Rod
Electrical Submersible Pump (ESP) System
Progressive Cavity Pump (PC Pump) System
Gas Lift Production Equipment
Truck-mounted Swabbing Unit
Wellhead and Christmas Tree
Heavy Oil Production Equipment
Water Flooding Equipment
Tertiary Recovery Equipment
Fracturing and Acidizing Equipment
Well Washing and Wax Removing Trucks

Part 1  Pumping Unit

The Chinese manufacturers started to produce pumping units in 1950’ s and have been API and ISO 9000 certified ever since 1980’ s.

Annual production capability of pumping unit: 20, 000 sets

Standard: API spec11E and China oil & gas industry standard

Models of pumping units: All API models, up to 1280, 000 in.-lbs

Torque range of reducer: 25, 50, 80, 114, 160, 228, 320, 456, 640, 912, 1280 (¡Á1000) in.-lbs

Suspension Load: 5, 300-36, 500 lbs

Stroke Length: 30-192 in

CPTDC has provided the China-made pumping units to the United States, Russia, Indonesia, Sudan and Venezuela.

  Features

    The strength of critical parts is calculated and checked by using finite element analysis.

    Special clamping fixtures and instruments are used in the manufacturing process of the main components to ensure proper fit and performance.

    Every unit has type approval test.

    Modular design allows parts to be easily interchanged and replaced.

1. Conventional Walking Beam Pumping Unit

Main specifications of conventional beam pumping unit according to API standards

Model (API)

Rated torque (lbs. in)

Load (lbs)

Stroke (in)

Main specifications of conventional beam pumping unit according to API standards

Model (API)

Rated torque (lbs. in)

Load (lbs)

Stroke (in)

C-1280-305-240

1, 280, 000

30, 500

240, 209, 179, 151

C-912-365-192

C-912-365-168

C-912-365-144

C-912-427-144

C-912-305-192

C-912-305-168

912, 000

36, 500

36, 500

36, 500

42, 700

30, 500

30, 500

192, 165, 138

168, 144, 121

144, 123, 102

144, 123, 102

192, 168, 145

168, 144, 121

C-640-365-168

C-640-305-192

C-640-305-168

C-640-365-144

C-640-305-144

C-640-256-144

C-640-256-192

C-640-305-120

640, 000

36, 500

30, 500

30, 500

36, 500

30, 500

25, 600

25, 600

30, 500

168, 144, 121

192, 168, 144

168, 144, 121

144, 123, 102

144, 123, 102

144, 123, 102

192, 165, 142

120, 102, 84

C-456-305-168

C-456-305-144

C-456-256-144

C-456-365-120

C-456-305-120

C-456-256-120

C-456-213-168

C-456-213-120

C-456-256-100

456, 000

30, 500

30, 500

25, 600

36, 500

30, 500

25, 600

21, 300

21, 300

25, 600

168, 144, 121

144, 123, 102

144, 123, 102

120, 102, 84

120, 102, 84

120, 102, 84

168, 145, 124

120, 102, 84

100, 85, 70

C-320-256-144

C-320-256-120

C-320-213-120

C-320-305-100

C-320-256-100

C-320-256-86

C-320-213-86

C-320-246-74

320, 000

25, 600

25, 600

21, 300

30, 500

25, 600

24, 600

21, 300

24, 600

144, 123, 102

120, 102, 84

120, 102, 84

100, 85, 70

100, 85, 70

86, 74, 62

86, 74, 62

74, 64, 53


C-228-185-144

C-228-213-120

C-228-213-100

C-228-173-120

C-228-173-100

C-228-246-86

C-228-213-86

C-228-200-74

C-228-173-74

228, 000

18, 500

21, 300

21, 300

17, 300

17, 300

24, 600

21, 300

20, 000

17, 300

144, 127, 109

120, 102, 84

100, 86, 72

120, 102, 84

100, 86, 72

86, 74, 62

86, 74, 62

74, 64, 53

74, 64, 53

C-160-173-100

C-160-173-86

C-160-200-74

C-160-173-74

C-160-143-74

160, 000

17, 300

17, 300

20, 000

17, 300

14, 300

100, 86, 72

86, 74, 62

74, 64, 53

74, 63, 52

74, 63, 52

C-114-119-100

C-114-119-86

C-114-143-74

C-114-173-64

C-114-143-64

C-114-173-54

114, 000

11, 900

11, 900

14, 300

17, 300

14, 300

17, 300

100, 86, 72

86, 73, 60

74, 63, 52

64, 55, 45

64, 53, 42

54, 44, 34

C-80-89-64

C-80-67-64

80, 000

8, 900

6, 700

74, 64, 54

64, 48, 36

C-57-109-48

C-57-95-48

C-57-89-42

C-57-76-54

C-57-76-42

57, 000

10, 900

9, 500

8, 900

7.600

7, 600

48, 37, 23

48, 37, 23

42, 33, 23

54, 45, 36

42, 33, 23

C-40-76-48

C-40-89-42

C-57-76-42

C-40-89-36

40, 000

7, 600

8, 900

7, 600

8, 900

48, 37, 23

42, 33, 23

42, 33, 23

36, 28, 20

C-25-67-36

C-25-56-36

C-25-67-30

C-25-53-30

25, 000

6, 700

5, 600

6, 700

5, 300

36, 28, 20

36, 28, 20

30, 20

30, 20

Conventional Pumping Units manufactured according to China National Standard

  Models and Specifications

Model (CYJ)

Rated torque of

reducer kN.m (lbs.in)

Max rod load

kN. (lbs)

Max Stroke

m (in)

CYJ3-1.8-13HB

CYJ5-1.8-13HB

CYJ5-2.1-13HB

CYJ6-2.5-26HB

CYJ8-3-48HB

CYJ10-3-37HB

CYJ10-3-53HB

CYJ12-5-73HB

CYJ16-6-105HB

CYJ11-3-48HB

CYJ12-3.2-70HB

CYJ12-3.6-73HB

CYJ12-4.2-73HB

CYJ12-4.8-73HB

CYJ12-5-73HB

CYJ14-5.5-105HB

CYJ16-6-105HB

CYJ20-4.2-53HB

13 (114, 000)

13 (114, 000)

13 (114, 000)

26 (228, 000)

48 (420, 000)

37 (320, 000)

53 (456, 000)

73 (640, 000)

105 (912, 000)

48 (420, 000)

70 (610, 000)

73 (640, 000)

73 (640, 000)

73 (640, 000)

73 (640, 000)

105 (912, 000)

105 (912, 000)

53 (456, 000)

30 (6, 700)

50 (11, 200)

50 (11, 200)

60 (13, 200)

80 (17, 300)

100 (21, 300)

100 (21, 300)

120 (25, 600)

160 (36, 500)

110 (24, 600)

120 (25, 600)

120 (25, 600)

120 (25, 600)

120 (25, 600)

120 (25, 600)

140 (31, 500)

160 (36, 500)

200 (42, 600)

1.8 (71)

1.8 (71)

2.1 (83)

2.5 (98)

3 (118)

3 (118)

3 (118)

5 (196)

6 (236)

3 (118)

3.2 (130)

3.6 (142)

4.2 (165)

4.8 (189)

5 (197)

5.5 (216)

6 (236)

4.2 (165)

2. Special Pumping Unit

Double Horse-head Walking Beam Pumping Unit

The rear part of this unit is a changing radius arc connected to the equalizer beam by a flexible joint. This configuration eliminates the dead angle restriction, enlarges the walking beam pivot range, and increases the stroke by 20% to 70%. In working condition, the regular changing length of rear part makes the counterbalance moment increase and decrease along with load increasing and decreasing. This structure makes the whole unit with low fluctuation, good balanced state and reduces energy consumption by 30% to 60%.

  Models and Specifications of Double Horse-head Pumping Units

Model (API)

Rated torque of

Reducer (lbs. in)

Max rod load

lbs

Stroke

in

CA640-365-240

CA640-305-200

CA640-256-200

CA456-305-200

CA456-256-200

CA320-256-200

CA320-213-200

CA228-173-120

640, 000

640, 000

640, 000

456, 000

456, 000

320, 000

320, 000

228, 000

36, 500

30, 500

25, 600

30, 500

25, 600

25, 600

21, 300

17, 300

240, 192, 144

200, 160, 120

200, 160, 120

200, 160, 120

200, 160, 120

200, 160, 120

200, 160, 120

120, 104, 84

Model (CYJ)

Rated torque of

reducer (kN.m)

Max rod load

kN

Stroke

m

YCYJ16-6-89HB

YCYJ16-6-73HB

YCYJ14-5-73HB

YCYJ12-5-73HB

YCYJ14-5-53HB

YCYJ12-5-53HB

YCYJ12-5-48HB

YCYJ10-5-48HB

YCYJ10-5-37HB

YCYJ8-3-26HB

YCYJ6-3-18HB

YCYJ4-2.5-13HB

YCYJ3-2.5-9HB

89

73

73

73

53

53

48

48

37

26

18

13

9

160

160

140

120

140

120

120

100

100

80

60

40

30

6, 4.8, 3.6

6, 4.8, 3.6

5, 4, 3

5, 4, 3

5, 4, 3

5, 4, 3

5, 4, 3

5, 4, 3

5, 4, 3

3, 2.6, 2.1

3, 2.6, 2.1

2.5, 2.1, 1.8

2.5, 2.1, 1.8

CYJBL10-4.2-37HB

CYJBL8-3-26HB

CYJBL6-2.5-18HB

CYJBL10-3-26HB

37

26

48

26

100

80

60

100

3, 3.6, 4.2

1.8, 2.4, 3

1.8, 2.5

3, 2.4, 1.8


Phased Crank Counterbalance Pumping Unit

The main difference between this pumping unit and the conventional pumping unit is that a phase angle between crank pin center line and counterbalance weight centerline causes the movement of crank shaft out of phase with the torque produced by load. This structure makes the net torque curve smooth, reduces the peak torque value, prolongs service life and reduces energy consumption.

  Models and Specifications of Phased Crank Counterbalance Pumping Units

Model (CYJY)

CYJY4-1.5-9HB

CYJY5-2.5-26HB

CYJY10-3-37HB

CYJY12-3.6-53HB

CYJY10-4.2-53HB

Model (API)

80-89-59

228-110-100

320-213-120

456-256-144

456-213-168

Rated rod load kN (lbs)

40 (8, 900)

50 (11, 000)

100 (21, 300)

120 (25, 600)

100 (21, 300)

Rated torque of reducer kN.m (lbs. in)

9 (80, 000)

26 (228, 000)

37 (320, 000)

53 (456, 000)

Drive ratio of reducer

31.73

29.5

29.43

30.8

SPM-Max
s/min

15

16

14

12

10

Stroke mm (in)

1, 500/59

2, 540/100

3, 000/120

3, 600/144

4, 200/168

1, 200/47

2, 110/79

2, 400/94

3, 000/120

3, 600/144

900/35

1, 535/60

1, 800/71

2, 390/94

3, 000/120

 

Model (CYJY)

CYJY16-4.2-73HB

CYJY12-4.8-73HB

CYJY14-5.5-89HB

CYJY16-6-105HB

Model (API)

640-365-168

640-256-192

773-305-216

912-365-240

Rated rod load kN (lbs)

160 (36, 500)

120 (25, 600)

140 (30, 500)

160 (36, 500)

Rated torque of reducer kN .m (lb. in)

73 (640, 000)

89 (773, 000)

105 (912, 000)

Drive ratio of reducer

31.73

39.25

35.43

SPM-Max s/min

9

8

8

  Stroke mm (in)

4, 200/168

4, 878/192

5, 500/216

6, 096/240

3, 600/144

4, 013/158

4, 800/189

5, 200/204

3, 000/120

3, 226/127

4, 200/168

4, 500/177



Bent Beam Pumping Unit

The rear of the walking beam is a bent shape that provides more posts for adjusting beam balance as required.

The balance movement of the walking beam varies as the horse-head moves up and down. The bent end of the walking beam modifies the crank balance curve, and the compound torque curve conforms to the load torque curve, smoothing out and reducing peaks in the net torque curve. This reduces the rated torque of the gear reducer and rated power of electric motor, putting structural parts under less stress and reducing power consumption by over 30%.

  Models and Specifications of Bent Beam Pumping Units

Model (API)

Rated torque of reducer (lbs.in)

Max rod load

lbs

Stroke (in)

Model (CYJ)

Rated torque of  reducer

 (kN.m)

Max rod load

kN

Stroke (m)

CB912-365-216

CB912-365-192

CB912-365-168

CB912-305-192

CB912-305-168

CB640-365-192

CB640-365-168

CB640-305-192

CB640-305-168

CB456-305-192

CB456-305-168

CB456-305-144

CB320-256-192

CB320-256-168

CB320-256-144

CB320-256-120

CB320-213-192

CB320-213-168

CB228-213-144

CB228-213-120

CB160-173-120

CBl14-133-120

912, 000

912, 000

912, 000

912, 000

912, 000

640, 000

640, 000

640, 000

640, 000

456, 000

456, 000

456, 000

320, 000

320, 000

320, 000

320, 000

320, 000

320, 000

228, 000

228, 000

160, 000

114, 000

36, 500

36, 500

36, 500

30, 500

30, 500

36, 500

36, 500

30, 500

30, 500

30, 500

30, 500

30, 500

25, 600

25, 600

25, 600

25, 600

21, 300

21, 300

21, 300

21, 300

17, 300

13, 300

216, 192, 168

192, 168, 144

168, 144, 120

192, 168, 144

168, 144, 120

192, 168, 144

168, 144, 120

192, 168, 144

168, 144, 120

192, 168, 144

168, 144, 120

144, 120, 86

192168, 144

168, 144, 120

144, 120, 86

120, 100, 74

192, 168, 144

168, 144, 120

144, 120, 86

120, 100, 86

120, 100, 86

120, 100, 86

CYJU16-5.5-105F

CYJU 16-4.8-105F

CYJU 16-4.2-105F

CYJU16-4.8-89F

CYJU 16-4.2-89F

CYJU14-4.8-105F

CYJU 14-4.2-105F

CYJU14-4.8-89F

CYJU14-4.2-89F

CYJU14-4.8-73F

CYJU14-4.2-73F

CYJUI4-3.6-73F

CYJU 12-4.8-53F

CYJU12-4.2-53F

CYJU12-3.6-53F

CYJU12-3-53F

CYJU10-4.8-48F

CYJU10-4.2-48F

CYJU10-3.6-37F

CYJU10-3-37F

CYJU8-3-26F

CYJU6-3-18F

105

105

105

89

89

105

105

89

89

73

73

73

53

53

53

53

48

48

37

37

26

18

160

160

160

160

160

140

140

140

140

140

140

140

120

120

120

120

100

100

100

100

80

60

5.5, 4.7, 4

4.8, 4.2, 3.6

4.2, 3.6, 3

4.8, 4.2, 3.6

4.2, 3.6, 3

4.8, 4.2, 3.6

4.2, 3.6, 3

4.8, 4.2, 3.6

4.2, 3.6, 3

4.8, 4.2, 3.6

4.2, 3.6, 3

3.6, 3.2, 2.1

4.8, 4.2, 3.6

4.2, 3.6, 3

3.6, 3, 2.1

3, 2.5, 1.8

4.8, 4.2, 3.6

4.2, 3.6, 3

3.6, 3, 2.1

3, 2.5, 1.8

3, 2.5, 2.1

3, 2.5, 2.1

Compound Balance Pumping Unit

Compound balance pumping units are similar to conventional pumping units, but there is a balancing counterweight on the rear end of the beam to balance the load jointly with the crank balance. The working principle is also similar to that of conventional units, but the beam balance spreads out the peak load to improve the balancing effect and decrease stress on the bar members.

  Models and Specifications of Compound Balance Pumping Units

Model

Rated torque of reducer (kN.m)

Max rod load (kN)

Stroke (m)

CYJY4-1.5-9HF

9

40

0.9, 1.2, 1.5

CYJY5-1.8-13HF

13

50

0.9, 1.3, 1.8

CYJY6-2.5-26HF

26

60

1.2, 1.8, 2.5

CYJY6-2.5-18HF

18

60

1.2, 1.8, 2.5

CYJY6-2.5-26HF

26

80

1.8, 2.4, 2.5

CYJY10-3-37HF

37

100

1.8, 2.4, 3


Front-mounted Crank Balance Pumping Unit

The construction of front mounted pumping units is quite different from that of conventional pumping units. The pitman, crank mechanism and horse-head are all mounted on the front side of the samson post bearing, and the balance counterweight and pitman are mounted on each end of the crank. These pumping units have the advantages of longer strokes and lower power use.

  Models and Specifications of Front-mounted Crank Balance Pumping Units

Model (CYJ)

CYJQ12-3.6-
 37HB

CYJQ12-3.6-53HB

CYJQ14-4.2-53HB

CYJQ14-3.6-73HB

CYJQ14-4.2-73HB

Model (API)

320-256-144

456-256-144

456-305-168

640-305-144

640-305-168

Rated rod load kN (lbs)

120 (25, 600)

120 (25, 600)

140 (30, 500)

140 (30, 500)

140 (30, 500)

 

Rated torque of reducer kN.m (lbs.in)

37 (320, 000)

53 (456, 000)

73 (640, 000)

Drive ratio of reducer

30.68

30.8

31.73

SPM-Max
s/min

12

12

10

12

10

Stroke mm (in)

3, 658/144

3, 656/144

4, 267/168

3, 658/144

4, 267/168

3, 251/128

3, 251/128

3, 785/149

3, 251/128

3, 785/149

2, 845/112

2, 845/112

3, 302/130

2, 854/112

3, 302/130

Model (CYJ)

CYJQ14-4.8

-73HB

CYJQ14-4.2

-105HB

CYJQ14-4.8

-105HB

CYJQ14-5.5

-105HB

CYJQ16-6

-105HB

Model (API)

640-305-192

912-305-168

912-305-192

912-305-216

912-365-240

Rated rod load kN (lbs)

140 (30, 500)

140 (30, 500)

140 (30, 500)

140 (30, 500)

160 (36, 500)

Rated torque of reducer kN.m
(lbs in)

73 (640, 000)

105 (912, 000)

Drive ratio of reducer

31.73

35.43               79.43

SPM-Max s/min

8

10

8

Stroke mm (in)

4, 877/192

4, 267/168

4, 877/192

5, 486/216

6, 000/240

4, 267/168

3, 785/149

4, 267/168

4, 877/192

5, 000/196

3, 658/144

3, 302/130

3, 658/144

4, 242/167

4, 000/157

Numerically Controlled Pumping Unit

The features of numerical control pumping unit are as follows:

  The speed regulation of up-stroke and down-stroke of numerically controlled pumping units is stepless. The Max stroke length is 12 m (which can be lengthened according to the customer’s requirements). The running conditions of the unit are extremely smooth with surge absorption. Its load capacity reaches 200 kN.

  Compact construction: The overall size is 3.2 m×1.2 m×1.2 m.
It is particularly suitable for production on offshore platform.

  The modular design of main components ensures the interchangeability of components and easy maintenance and service.

  Adopting AC frequency conversion and computer-aided technology for speed control, easy for operation and energy saving.

  Models and Specifications of Numerically Controlled Pumping Units

Model

Rated torque

kN.m (lb¡¤in)

Max load

kN (lbs)

Motor power kW (HP)

Max stroke

m (in)

SKC6-4-7.2

SKC6-5-7.2

SKC6-6 -12

SKC6-8-12

SKC6-10-12

SKC8-6-12

SKC8-8-18

SKC8-10-18

SKC10-6-18

SKC10-8-18

SKC10-10-18

SKC12-6-18

SKC12-8-18

SKC12-10-18

SKC12-12-30

SKC14-6-18

SKC14-8-18

SKC14-10-30

SKC14-12-30

SKC16-6-18

SKC16-8-18

SKC16-10-30

SKC16-12-30

SKC20-6-30

SKC20-8-30

SKC20-l 0-60

SKC20-12-60

7.2 (63, 763)

7.2 (63, 763)

12 (106, 272)

12 (106, 272)

12 (106, 272)

12 (106, 272)

18 (159, 408)

18 (159, 408)

18 (159, 408)

18 (159, 408)

18 (159, 408)

18 (159, 408)

18 (159, 408)

18 (159, 408)

20 (177, 120)

18 (159, 408)

18 (159, 408)

30 (265, 680)

30 (265, 680)

18 (159, 408)

18 (159, 408)

30 (265, 680)

30 (265, 680)

30 (265, 680)

30 (265, 680)

60 (531, 360)

60 (531, 360)

60 (13, 500)

60(13, 500)

60 (13, 500)

60 (13, 500)

60 (13, 500)

80 (18, 000)

80 (18, 000)

80 (18, 000)

100 (22, 500)

100 (22, 500)

100 (22, 500)

120 (27, 000)

120 (27, 000)

120 (27, 000)

120 (27, 000)

140 (31, 500)

140 (31, 500)

140 (31, 500)

140 (31, 500)

160 (36, 000)

160 (36, 000)

160 (36, 000)

160 (36, 000)

200 (45, 000)

200 (45, 000)

200 (45, 000)

200 (45, 000)

11-22 (14.96-29.92)

11-22 (14.96-29.92)

15-30 (20.4-40.8)

15-30 (20.4-40.8)

15 -30 (20.4-40.8)

15-30 (20.4-40.8)

15-30 (20.4-40.8)

15-30 (20.4-40.8)

15-30 (20.4-40.8)

15-30 (20.4-40.8)

15-30 (20.4-40.8)

15-30 (20.4-40.8)

15-30 (20.4-40.8)

15-30 (20.4-40.8)

22-55 (29.92-74.8)

15 -30 (20.4-40.8)

15-30 (20.4-40.8)

22-55 (29.92-74.8)

22-55 (29.92-74.8)

15-30 (20.4-40.8)

15-30 (20.4-40.8)

22-55 (29.92-74.8)

22-55 (29.92-74.8)

22-55 (29.92-74.8)

22-55 (29.92-74.8)

37-75 (50.32-102)

37-75 (50.32-102)

4 (157.5)

5 (196.8)

6 (236.2)

8 (315)

10 (393.7)

6 (236.2)

8 (315)

10 (393.7)

6 (236.2)

8 (315)

10 (393.7)

6 (236.2)

8 (315)

10 (393.7)

12 (472.4)

6 (236.2)

8 (315)

10 (393.7)

12 (472.4)

6 (236.2)

8 (315)

10 (393.7)

12 (472.4)

6 (236.2)

8 (315)

10 (393.7)

12 (472.4)

Linear Motor Actuated Pumping Unit

The linear motor actuated pumping unit, different from traveling beam pumping unit, which converts electric power into rotation power at first and then into linear reciprocating movement in mechanical way, can directly convert electric power into linear reciprocating movement by using linear motor to simplify the mechanical drive process.

  Features

High transmission efficiency

Small dynamic and inertial load

Small energy consumption

Light weight

Long service life

Convenient for intellectualized and automatic control

Wide application scope

  Models and Specifications of Linear motor Actuated Pumping Unit

Model

Structure capacity  mt (lb)

Max stroke

M (ft)

Motor thrust

mt (lb)

Power

 (kW)

Zxcy5-3-15-

5 (11, 000

3 (10)

1.5 (3, 300)

9

Zxcy8-3-20-

8 (17, 000)

3 (10)

2.0 (4, 400)

13

Zxcy10-4.2-20-

10 (22, 000)

4.2 (14)

2.0 (4, 400)

18

Zxcy12-6-30-

12 (26, 000)

6 (20)

3.0 (6, 600)

24

Zxcy14-6-30-

14 (30, 000)

6 (20)

3.0 (6, 600)

30

Zxcy14-6-45-

14 (30, 000)

6 (20)

4.5 (9, 900)

30

Zxcy16-6-45-,

16 (35, 200)

6 (20)

4.5 (9, 900)

40

Zxcy16-6-60-,

16 (35, 200)

6 (20)

6.0 (13, 200)

40

Zxcy16-8-60-,

16 (35, 200)

8 (26)

6.0 (13, 200)

40

Zxcy18-6-45-,

18 (39, 600)

6 (20)

4.5 (9, 900)

54

Zxcy18-6-60-,

18 (39, 600)

6 (20)

6.0 (13, 000)

54

Zxcy18-8-60-,

18 (39, 600)

8 (26)

6.0 (13, 000)

54

Remarks:: Integrated, : Modular


Moving Belt Pumping Unit

The moving belt pumping unit is especially suitable for deep or high production well. The flow rate is up to
250 m3/d, also is suitable for heavy oil production. Compared with other artificial lift systems, the moving belt pumping unit has the following advantages:

Long, slow pump stroke

The stroke length can be as long as 7.3 m, significantly reducing downhole pump wear.

Saving power consumption by 10-40%

Smooth, noiseless and vibration-less operation

Compact profile, easy to ship and assemble

  Models and Specifications of Moving Belt Pumping Units

Model

900

800

700

600

Stroke length m (ft)

7.3 (23.95)

7.0 (22.96)

6.0 (19.68)

5.0 (16.4)

Peak polished rod load kg (lbs)

16, 310 (35, 957)

14, 000 (30, 864)

12, 000 (26, 455)

10, 000 (22, 045)

SPM-Max s/min

4

5.3

SPM-Min s/min

No Absolute Minimum

Shipping weight kg (lbs)

19, 500 (42, 900)

17, 500 (38, 580)

15, 500 (34, 171)

13, 500 (29, 762)

Unit width m (ft)

2.4 (7.87)

2.2 (7.22)

Unit height m (ft)

12.4 (40.68)

11.1 (36.42)

10.1 (33.14)

9.2 (30.18)

Gear Reducer

  Two types of gear tooth profiles

    Involutes profile tooth-conforming to API Spec11E

    Double circular arc tooth profile-invented in China, now widely used

  Features

Smooth running, small size, low noise and high load capacity

3. Electrical Motor

The electrical motors include synchronous motors and asynchronous motors, which can be classified according to rotation speed and control mode (Low rotation speed or high rotation speed, VFD control or FFD control electrical motors are available).

YCH Series High Slip Induction Motor

Enclosure: Totally Enclosed Fan Cooled (TEFC)

Frame Material: Cast Aluminum.

Insulation Class: E                   

YCH Series High Slip Induction Motors

Temperature rise: 80 , Class B

Voltage: 460 V/60 Hz/3 Phase,

NEMA Design: D (7.5% Slip), Service Factor: 1.15

Starting condition: Full Voltage, Space Heater: 12 V A.C.

Environmental Exposure: Fungus and High Humidity

Thermal protection with three (3) thermostats (1 per phase)

   Models and Specifications of NEMA D Series High Slip Motors

Synchronization speed: 1200 RPM 460 V 60 Hz

Model

Frame

Nameplate horsepower

Full load amp.

Full load RPM

Slip

Efficiency

Power factor

L.R. Torque (N.m)

Locked rotor Amp.

YCH180-6

286T

20 (15 kW)

26.3

1, 111

 7.41

83.00

0.861

326

130

YCH200-6

326T

30 (22 kW)

37.9

1, 104

7.98

83.39

0.873

438

175

YCH200-1-6

326T

35 (25 kW)

43.3

1, 121

6.57

85.47

0.843

690

252

YCH225-6

365T

50 (37 kW)

60.9

1, 105

7.88

84.32

0.904

863

318

YCH250-6

405T

60 (45 kW)

73.0

1, 119

6.68

85.75

0.903

1, 102

425

YCH280-6

445T

85 (63 kW)

101.4

1, 119

6.76

86.29

0.904

1, 898

647

YCH280L-8

445T

100 (75 kW)

120.7

1, 114

7.19

86.49

0.902

3, 041

858

Synchronization speed: 900  RPM 460 V 60 Hz

YCH180-8

286T

15 (11 kW)

21.9

824

8.36

80.70

0.781

296

88.5

YCH200-8

326T

20 (15 kW)

29.6

833

7.42

83.01

0.767

437

130

YCH200-1-8

326T

25 (18.5 kW)

36.8

832

7.55

83.26

0.759

618

170

YCH225-8

365T

35 (25 kW)

46.0

839

6.74

85.04

0.802

1, 010

263

YCH250-8

405T

45 (33 kW)

59.6

840

6.71

85.33

0.829

1, 193

328

YCH280-8

445T

60 (45 kW)

79.1

834

7.35

85.18

0.839

1, 865

454

YCH280L-8

445T

75 (55 kW)

93.9

840

6.69

86.40

0.851

2, 051

546

Synchronization speed: 1000 RPM 380 V 50 Hz

YCH180-8

286T

10 (7.5 kW)

19.1

686

8.50

79.39

0.750

285

80

YCH200-8

326T

15 (11 kW)

27.4

688

8.22

81.15

0.750

428

118

YCH200-1-8

326T

20 (15 kW)

36.6

689

8.10

81.62

0.763

545

157

YCH225-8

365T

25 (18.5 kW)

42.8

694

7.50

83.41

0.787

965

235

YCH250-8

405T

35 (25 kW)

55.4

693

7.66

83.57

0.821

1, 151

296

YCH280-8

445T

45 (33 kW)

72.7

689

8.08

83.73

0.824

1, 761

405

YCH280L-8

445T

60 (45 kW)

95.1

688

8.33

84.05

0.855

1, 986

494


Synchronization speed: 750 RPM 380 V 50 Hz

YCH180-8

286T

15 (11 kW)

21.9

824

8.36

80.70

0.781

296

88.5

YCH200-8

326T

20 (15 kW)

29.6

833

7.42

83.01

0.767

437

130

YCH200-1-8

326T

25 (18.5 kW)

36.8

832

7.55

83.26

0.759

618

170

YCH225-8

365T

35 (25 kW)

46.0

839

6.74

85.04

0.802

1, 010

263

YCH250-8

405T

45 (33 kW)

59.6

840

6.71

85.33

0.829

1, 193

328

YCH280-8

445T

60 (45 kW)

79.1

834

7.35

85.18

0.839

1, 865

454

YCH280L-8

445T

75 (55 kW)

93.9

840

6.69

86.40

0.851

2, 051

546

Energy-saving Package Transformer and Control Box

   Specifications of Energy-Saving Package Transformers

Voltage kV

Weight

Overall dimensions (L¡ÁW¡ÁH)

HT

LT

kg

lbs

mm

in

30

415

915

990×650×1, 140

38.9×25.5×44.8

50

522

1, 150

1, 070×690×1, 190

42.1×27.1×46.8

63

590

1, 300

1, 090×711×1, 210

42.9×27.9×47.6

80

643

1, 417

1, 210×780×1, 374

47.6×30.7×54.0

100

0.38

755

1, 644

1, 230×870×1, 160

48.4×34.2×45.6

125

885

1, 951

1, 330×900×1, 240

52.3×35.4×48.8

160

1, 025

2, 259

1, 480×910×1, 280

58.2×35.8×50.3

200

1, 166

2, 570.5

1, 500×920×1, 300

59.0×36.2×51.1

250

1, 245

2, 744.7

1, 410×1, 000×1, 540

55.5×39.3×60.6

315

1, 430

3, 152.5

1, 460×1, 010×1, 680

57.4×39.7×66.1

   Specifications of Control Box

Model

Voltage kV

Current A

Overall dimensions (L¡ÁW¡ÁH)

QYK-A

600-2, 500

QYK-B

600-2, 500

100

960×702×1, 730 (37.7×27.6×38.1)

WZK-100

900-2, 500

760×563×1, 650 (29.9×22.1×64.9)

QYK-500

500-1, 200

150

600×550×1, 600 (23.6×21.7×63.0)

QYK-1200

1200-3, 000

100

600×550×1, 600 (23.6×21.7×63.0)

Rare Earth Permanent Magnet Three Phase Synchronous Motor

Permanent magnet synchronous motors with large starting torque can reduce energy consumption than asynchronous motors by 25%. A 37 kW synchronous motor can replace a 55 kW asynchronous motor. These motors can realize asynchronous starting and synchronous running. They have the same size of Y-series asynchronous motors. Stator construction is similar to that of asynchronous motors, and F grade insulation is used. The motor includes two parts: squirrel-cage and permanent magnet.

   Models and Specifications of Rare Earth Permanent Magnet 3-Phase Synchronous Motors

Model

Rated

power

Rated speed

Max torque

multiple

Rated cable

voltage

Rated

efficiency

Starting

torque multiple

Rated

frequency

Rated power

factor

Starting current

multiple

YJ43

37 kW

1, 000 rpm

1.7

380 V

93.8%

3.0

50 Hz

0.93

11

YJ44

37 kW

750 rpm

1.7

380 V

94.2%

3.0

50 Hz

0.93

10.5

  Copyright 2003-2008, PetroChina Company Limited, All Rights Reserved Contact Us | Site map | Disclaimer