| Part 7 Others | | 1. Flow Meter | | | | UF-Ⅱ Flow meter | DN: 80, 100, 150, 200, 250, 300, 400 mm Accuracy: ±0.2%, ± 0.5% Flow range: 12-2, 800 m3/h Max operating temperature: +120 ℃ Material: ZG 25 for meter body, HT250 for wet parts, carbon bearing Specially contoured tooth shape of a pair of spiral rotor resulting in no pulsation and low noise Widely applied in petrochemical industry | | | | Series LC Oval Flow Meter | DN: Ф10, 15, 20, 25, 40, 50, 80, 100, 150, 200 mm Flow range: 0.08-340 m3/h | | | | ● Data Sheet | | Material | Cast iron: (A) | Cast steel: (E) | Stainless steel:(B) | | Pressure (MPa) | 1.6 | 6.4 | 1.6,2.5 | | Temperature | -20 ℃-+100 ℃ | -20 ℃-+100 ℃ | -20 ℃-+80 ℃ |
| | | | Series OI Oval Flow Meter | Accuracy:±0.2%, ± 0.5%; repeatable error is less than 1/3 of intrinsic error limit Measured media viscosity: 0.3-3, 000 mPa·s; for media's viscosity larger than 3, 000 mPa·s, a high-viscosity Oval flow meter is applicable. |  | | | Measured media temperature: 0-90 ℃ (for standard type), 90 ℃-110 ℃ (with a heat extension for high temperature type) Body material: cast steel, stainless steel (F5: OCr18Ni12Mo2Ti; F8: OCr18Ni9Ti) Flow range: | | | | ● Small-type flow meter: | | Basic type | OI03 | OI06 | OI1(K) | OI2 | | DN(mm) | 6 | 10 | 15(25) | 20 | | Rated flow rate (L/h) | 120 | 250 | 600 | 1, 800 |
| | | | ● Standard-type flow meter: | | Basic type | OI5(K) | OI1O(K) | OI50 | OI200 | OI40 | | DN(mm) | 5(32) | 25(40) | 50 | 80 | 100 | | Rated flow rate (m3/h) | 3 | 6 | 18 | 42 | 72 |
| | | | Series VA Vortex Flow Meter | DN for Clipping type: Ф25, 40, 50, 80, 100, 150, 200, 250, 300 mm Flow range ratio: 10:1-10: Accuracy:±1.0% Repeatability: ±0.2% Max Operating Pressure: 4.0 MPa Fluid temperature: -40-+300 ℃ Applicable media: liquid , gas, steam ( saturated, overheated) Shock-resistance: ≤1.0g DN: Ф350-2, 000 mm Model VA-X (D) Smart Vortex Flow Meter Model VA-X: extant +24VDC Power Model VA-X (D): internal power supply for more than one year Six-digit LCD display, clear, Model VA-Q submarine vortex flow transmitter is applicable in the wet and moisture environment or place where signal wire leads to the ground from water pipe. Get more and better Call 0551-3422670. |  | | | | Bst Ultra-Sonic Flow Meter | Install outside the pipe; on site flow display; Two categories a: Time differential meter Accuracy level: 1.0, 1.5 Flow range: 0.05 m/s-10.0 m/s Pipe diameter: 8-3, 000 mm with a wall thickness of less than 35 mm Measured media: clean liquids such as: water, supply, industrial water, cycled water, chemical solvents b: Doppler meter: Accuracy level: 1.0 Flow range: 0.3 m/s-10.0 m/s Pipe diameter: 25-1, 400 mm with a wall thickness of less than 35 mm Measured media: unclean liquids such as waste water, pulp, heavy oil , crude oil and two-phase or multi-phase liquids |  | | | | Mob Electro-Magnetic Flowmeter | Nominal diameter: 20-300 mm Ambient temperature: -10 ℃-+45 ℃ Accuracy class: 0.5, 1 Flow range: within flow rate of 1-10 m/s, and may be extended to a flow rate of 0.5-10 m/s Rated operational pressure:1.0,1.6, 2.5 MPa Power supply: 220 VAC±10%, 50 Hz±5% Output signal: 4-20 mA Load resistance: 0-500 Ω Applied for the measurement of Electro-conductive liquids. |  | | | | | | | | | | Page 1 2 3 4 5 6 7 |
|
|
|
|
|
|
|
|
|
|
|
|